Download AWWA standard for polyvinyl chloride (PVC) water by American Water Works Association.; American National PDF

Posted by

By American Water Works Association.; American National Standards Institute

Show description

Read or Download AWWA standard for polyvinyl chloride (PVC) water transmission pipe, nominal diameters 14 in. through 36 in PDF

Similar nonfiction_12 books

Process-Oriented Dynamic Capabilities: Framework Development, Empirical Applications and Methodological Support

​This ebook introduces a process-oriented dynamic power framework to review either, provider innovation and enterprise strategy administration (BPM). effects from purposes in numerous case reports and surveys are pronounced. They replicate, e. g. , strength improvement and adulthood types. according to those findings, a mode to help carrier innovation is brought.

Transactions on Computational Collective Intelligence XVI

Those transactions submit study in computer-based equipment of computational collective intelligence (CCI) and their purposes in a variety of fields comparable to the semantic internet, social networks, and multi-agent structures. TCCI strives to hide new methodological, theoretical and useful points of CCI understood because the type of intelligence that emerges from the collaboration and festival of a lot of people (artificial and/or natural).

Computer Arithmetic: Pergamon Programmed Texts

Laptop mathematics offers details pertinent to the basic elements of a electronic machine. This booklet discusses how the keep an eye on unit makes use of the mathematics unit to provide, lower than instructions, the solutions requested by way of the person. prepared into 4 chapters, this e-book starts with an outline of the binary code and offers a preview of using different mathematics codes open air the pc.

Extra info for AWWA standard for polyvinyl chloride (PVC) water transmission pipe, nominal diameters 14 in. through 36 in

Example text

56 psi Continue this procedure for all stations. 4. 00 psi Licensee=ATLATEC S A DE C V/5972499002 Not for Resale, 03/18/2009 14:57:29 MDT PVC PRESSURE PIPE AND FABRICATED FITTINGS 21 Step 6: Select the appropriate pipe DR for each section of the pipeline. Step 3 determined that DR 21 has a WPR for this example of at least 128 psi. , the WPR of the next pipe DR in this example). The point at which the pressure drops to 98 psi is determined using the pressure gradient from station 80 + 00 to 160 + 00.

00 psi Licensee=ATLATEC S A DE C V/5972499002 Not for Resale, 03/18/2009 14:57:29 MDT PVC PRESSURE PIPE AND FABRICATED FITTINGS 21 Step 6: Select the appropriate pipe DR for each section of the pipeline. Step 3 determined that DR 21 has a WPR for this example of at least 128 psi. , the WPR of the next pipe DR in this example). The point at which the pressure drops to 98 psi is determined using the pressure gradient from station 80 + 00 to 160 + 00. , 330 ft downstream of 80 + 00). Thus, DR 25 can be used beginning at (80 + 00) + (3 + 30) = 83 + 30.

20 AWWA C905-97 Where: f Q di C = = = = = friction loss, ft of H2O/100 ft flow rate, in gallons per minute pipe internal diameter, in inches flow coefficient 150 for PVC pipe Substituting for 20-in. 118 psi per 100 ft of pipeline --``,,,,``,``,`,`,````,,`,,````-`-`,,`,,`,`,,`--- Step 5: Determine the working pressures at key points under steady state, full flow conditions. The working pressure (P), is the sum of the static head due to elevation and the friction loss. 56 psi Continue this procedure for all stations.